Technology & Advantage
Structure of System
Rotor
Joint of blades, shaft of wind turbine.
Lift Blades
As structure same with the wings of airplane, able to speed up many times the wind speed by accelerating through creating magnet.
Drag Blades
Proper to various kind of wind by delivering the power needed for initial start and easy to change the lift after accelerating drag.
Generator in a type of permanent magnet generator (PMG)
As there is no resistance to rotation according to no load even with no wind, PMG is excellent in case of not rotating for certain time and restoring energy in re-starting wind.
Controller
Device charging or controlling electrical energy generated to battery (charger)
Battery
Provide electricity to the places in need after saving generated electricity.
SPECIFICATION
MODEL : HE-300
General Specifications
Rated Output 300W
Rated Speed 855RPM
Rated Wind Velocity 12m/s
Start Wind Velocity < 3m/s
Stop Wind Velocity 15m/s
Survival Wind Velocity 60m/s
Size / Weight
Rotating Blade: Diameter 1.24m
Rotating Blade: Height 1.06m
Transmission Tower: Height 4m (min)
Total Height 5.06m (min)
Generator: Weight 30kg
Rotating Blade Specifications
External Darriues 3 Blades in total
Internal Savonius 2 Layers in total
Blade Material Aluminum alloy
Axis Material Zinc galvanizing SS400
General Specifications
Standard Type AC, 3 phade
Synchronism PMG
Rated Output 300W
Brake System
Auto Shory-circuit Braking System for overspeed
Manual Mechanical Drum Brake
Operating Conditions
Ambient Temperature -10 ~ 40°C
Ambient Humidity Up to 95%
※ This product has been tested in Antarctic natural environment with an average temperature of -30°C degree
Control system
Rated Output 300W
Rated Input Atypical Three-Phase 40V 12.5A
Input Frequency 50~60Hz
Output Frequency 50~60Hz
Output Format Direct Current
Voltage of Storage Battery 24V (12V)
Rated Output Single-phase DC 24V 12.5A
(12V 25A)
Overpower Control Auto Short-Circuit
Overvoltage Control Auto Short-Circuit
System Control Method Auto Short-Circuit
Product Warranty Period
Product Name Free Warranty Period Details
Wind Turbine 2 Years Wind Turbine Main Body
Electric and Electronic Parts 1 Years Inverter, Controller, Timer, Converter
Solar Panel, LED Lamp, etc
Structure 2 Years Support Structure
Etc – Subject to Manufacturer’s Warranty
KS Certification
MODEL : HE-700
General Specifications
Rated Output 700W
Rated Speed 405RPM
Rated Wind Velocity 12m/s
Start Wind Velocity < 3m/s
Stop Wind Velocity 15m/s
Survival Wind Velocity 60m/s
Size / Weight
Rotating Blade: Diameter 1.93m
Rotating Blade: Height 1.56m
Transmission Tower: Height 4m (min)
Total Height 5.56m (min)
Generator: Weight 60kg
Rotating Blade Specifications
External Darriues 3 Blades in total
Internal Savonius 2 Layers in total
Blade Material Aluminum alloy
Axis Material Zinc galvanizing SS400
General Specifications
Standard Type AC, 3 phade
Synchronism PMG
Rated Output 700W
Brake System
Auto Shory-circuit Braking System for overspeed
Manual Mechanical Drum Brake
Operating Conditions
Ambient Temperature -10 ~ 40°C
Ambient Humidity Up to 95%
※ This product has been tested in Antarctic natural environment with an average temperature of -30°C degree
Control system
Rated Output 700W
Rated Input Atypical three-phase 60V 15A
Input Frequency 50~60Hz
Output Frequency 50~60Hz
Output Format Direct Current
Voltage of Storage Battery 48V
Rated Output Single Phase DC 48V 15A
Overpower Control Auto Short-Circuit
Overvoltage Control Auto Short-Circuit
System Control Method Auto Short-Circuit
Product Warranty Period
Product Name Free Warranty Period Details
Wind Turbine 2 Years Wind Turbine Main Body
Electric and Electronic Parts 1 Years Inverter, Controller, Timer, Converter
Solar Panel, LED Lamp, etc
Structure 2 Years Support Structure
Etc – Subject to Manufacturer’s Warranty
KS Certification
MODEL : HE-1500
General Specifications
Rated Output 1500W
Rated Speed 250RPM
Rated Wind Velocity 12m/s
Start Wind Velocity < 3m/s
Stop Wind Velocity 15m/s
Survival Wind Velocity 60m/s
Size / Weight
Rotating Blade: Diameter 2.8m
Rotating Blade: Height 2.9m
Transmission Tower: Height 4m (min)
Total Height 6.9m (min)
Generator: Weight 300kg
Rotating Blade Specifications
External Darriues 3 Blades in total
Internal Savonius 2 Layers in total
Blade Material Aluminum alloy
Axis Material Zinc galvanizing SS400
General Specifications
Standard Type AC, 3 phade
Synchronism PMG
Rated Output 1500W
Brake System
Auto Shory-circuit Braking System for overspeed
Manual Mechanical Drum Brake
Operating Conditions
Ambient Temperature -10 ~ 40°C
Ambient Humidity Up to 95%
※ This product has been tested in Antarctic natural environment with an average temperature of -30°C degree
Control system
Rated Output 1500W
Rated Input Atypical three-phase 70V 23A
Input Frequency 50~60Hz
Output Frequency 50~60Hz
Output Format Direct Current
Voltage of Storage Battery 48V
Rated Output Single Phase AC 220V 12A
Overpower Control Auto Short-Circuit
Overvoltage Control Auto Short-Circuit
System Control Method Auto Short-Circuit
Product Warranty Period
Product Name Free Warranty Period Details
Wind Turbine 2 Years Wind Turbine Main Body
Electric and Electronic Parts 1 Years Inverter, Controller, Timer, Converter
Solar Panel, LED Lamp, etc
Structure 2 Years Support Structure
Etc – Subject to Manufacturer’s Warranty
KS Certification
MODEL : HE-3000
General Specifications
Rated Output 3000W
Rated Speed 180RPM
Rated Wind Velocity 12m/s
Start Wind Velocity < 3m/s
Stop Wind Velocity 15m/s
Survival Wind Velocity 60m/s
Size / Weight
Rotating Blade: Diameter 4m
Rotating Blade: Height 4.2m
Transmission Tower: Height 4m (min)
Total Height 8.2m (min)
Generator: Weight 680kg
Rotating Blade Specifications
External Darriues 3 Blades in total
Internal Savonius 2 Layers in total
Blade Material Aluminum alloy
Axis Material Zinc galvanizing SS400
General Specifications
Standard Type AC, 3 phade
Synchronism PMG
Rated Output 3000W
Brake System
Auto Shory-circuit Braking System for overspeed
Manual Mechanical Drum Brake
Operating Conditions
Ambient Temperature -10 ~ 40°C
Ambient Humidity Up to 95%
※ This product has been tested in Antarctic natural environment with an average temperature of -30°C degree
Control system
Rated Output 3000W
Rated Input Atypical three-phase 175V 17A
Input Frequency 50~60Hz
Output Frequency 50~60Hz
Output Format Direct Current
Voltage of Storage Battery 48V
Rated Output Single Phase AC 220V 24A
Overpower Control Auto Short-Circuit
Overvoltage Control Auto Short-Circuit
System Control Method Auto Short-Circuit
Product Warranty Period
Product Name Free Warranty Period Details
Wind Turbine 2 Years Wind Turbine Main Body
Electric and Electronic Parts 1 Years Inverter, Controller, Timer, Converter
Solar Panel, LED Lamp, etc
Structure 2 Years Support Structure
Etc – Subject to Manufacturer’s Warranty
KS Certification
Features of Wind Power
Comparison with our competitors
Efficient Wind Power
New Proposal for Urban Wind Power Generation
Problems of existing wind power and limit to application of urban generation caused by urban geological characteristics
Solving fundamental problems according to urban structure is essential element
In the geological structure of city, buildings case the ventilation pathway not to be smooth and its quality to be poor with turbulence. In addition, wind power can be developed even with upward current and turbulent current caused by the buildings and the only alternative can be provided with high efficiency caused by gentle wind and acceleration.
Limit to the installed places caused by noise during the generation.
Vertical axis type generator of HIENERGY doesn’t cause noise in generator and in case of being 5m/s or more of wind speed needed in the existing wind power generation, the power is generated at 1.2m/s and little noise is caused from blades. As the problem of noise is solved, it is easy to install the generator in the city and general building.
Consider the value in environmental design as the structure of the city.
The need of the value in environmental design other than the technology of urban generation has been raised when urban environmental design is regarded as essential elements. Vertical wind power generator of HIENERGY satisfies us in eco-friendly and aesthetic functions of public design as the modeling element.
Need for urban generation with high electricity demand
The electricity generated outside the city with low electricity demand needs a lot of transmission cost and electricity loss. Due to the need of urban generation used immediately after generation in most of urban area, the best wind power system is provided.
Solve the problems in space and technology according to electricity demand
The need of system tailored to geological and situational structure in the city with the need of electricity to rooftop of building, “Blower” (exhaust duct for ventilation), road and park is raised along with the need of system tailored to geological and situational structure of buildings. The tower type of generation system enabling exclusive system and variable generation tailored to various kinds of structure and urban structure of the buildings is offered.